Microsoft Outlookin ja Microsoft 365 -palveluissa on häiriö, joka voi vaikuttaa sähköpostien lähettämiseen ja vastaanottamiseen. Yhteydenottoihimme vastaaminen saattaa viivästyä. Asbesti- ja haitta-ainetutkimusten tilauslomakkeet toimivat normaalisti, ja tutkimustilauksia voi tehdä tavalliseen tapaan. Kiireellisissä asioissa pyydämme soittamaan numeroon 02 282 7780.

Temporary email service disruption

Microsoft Outlook and Microsoft 365 are currently experiencing a service disruption that may affect email delivery and receipt. Our response times may be longer than usual. Our asbestos and hazardous material analysis order forms are working normally, and orders can be submitted as usual. For urgent matters, please call +358 2 282 7780.

Corrosion mechanisms of Al‐alloyed hot‐dipped zinc coatings in wet supercritical carbon dioxide

03.11.2026
← Knowledge Hub

Research publication

Coatings and thin filmsCorrosionMetals and steel

Commercial hot‐dip galvanized zinc (Zn‐0.2% Al), galfan (Zn‐5% Al), and galvalume (Zn‐55% Al) coatings were exposed to wet scCO , followed by an assessment of microstructural changes in the coating structure. Zinc and galfan coatings showed similar surface activity with abundant zinc dissolution and uniform corrosion product deposition.

Year
2024
Material language
en
Authors / speakers
Ville Saarimaa
Aaretti Kaleva
Arnold Ismailov
Markus Virtanen
Erkki Levänen
Pasi Väisänen
Journal / publisher
Materials and Corrosion

Abstract

Abstract

Commercial hot‐dip galvanized zinc (Zn‐0.2% Al), galfan (Zn‐5% Al), and galvalume (Zn‐55% Al) coatings were exposed to wet scCO
2
, followed by an assessment of microstructural changes in the coating structure. Zinc and galfan coatings showed similar surface activity with abundant zinc dissolution and uniform corrosion product deposition. The Al‐rich phases of the galfan coating were intact in the studied atmosphere and eventually became embedded within the deposits. The zinc dissolution ended for zinc and galfan coatings when the free metal surface was blocked from the surrounding medium by a uniform corrosion product layer. Galvalume showed scarce reactivity: dissolution of zinc in the Zn‐rich interdendritic areas proceeded slowly compared to zinc and galfan, and the Al‐rich dendrites (with nm‐scale Zn inclusions) remained intact. The ion beam milling technique combined with modern nm‐resolution energy‐dispersive spectroscopy analysis enabled previously unseen visualization of the discussed corrosion processes.

Material and sources

DOI: 10.1002/maco.202314081